Coagulation and flocculation are essential components of both drinking water and wastewater treatment. They provide a reliable process for treating water turbidity (the cloudiness or haziness of a fluid typically invisible to the naked eye), which is a key test of water quality. In wastewater treatment, they enable up to 90% reduction in suspended solids and organic loads.
All waters contain suspended particles. The smallest particles (colloids) are stabilised by the action of physical forces (static electricity) on the particles themselves and, because they all have a negative charge when suspended in water, they repel each other. This causes them to remain suspended rather than clumping together and settling out of the water. They might take days or even up to centuries to settle out!
Coagulation and flocculation are two separate processes, used in succession, to overcome the forces stabilising the suspended particles. While coagulation neutralises the charges on the particles, flocculation enables them to bind together, making them bigger, so that they can be more easily separated from the liquid.LEARN ABOUT WATER TREATMENT SOLUTIONS
This destroys the process whereby tiny particles repel each other and promotes their consolidation to bigger ones that are able to stick together. The bigger the particle, the easier it is to separate from the liquid. The use of coagulants for treating water goes all the way back to around 2000 BC when the Egyptians used almonds, smeared around vessels, to treat river water.
These larger ‘clumps’ of particles are called micro-flocs and still cannot always be seen by the naked eye. The water surrounding these newly formed particles should be clear – and this will signal that the particles’ charges have been neutralised. If it isn’t, more coagulant may be needed. Too much coagulant and the particles will revert to repelling each other – but predominantly by the reverse charge.
Rapid mixing ensures the coagulant is properly dispersed to promote particle collisions. The metal coagulant hydrolysis products formed within 0.01 to 1.0 seconds tend to be the most effective for destabilisation – this is why adjustment of pH and post-dosing of more coagulant is rarely effective after the initial coagulant addition.
One common type of rapid mixer is called a back-mix reactor, which normally consists of square tanks with vertical impellers. In many instances, they produce poor results, and WCS tends to design in-line mixers with velocity gradient control to provide the best conditions for rapid mixing.
Today, there are two types of coagulants most commonly used in water and wastewater treatment: organic and inorganic.
Organic coagulants include polyamines, polydiallyldimethylammonium chloride (Poly DADMACs) and polytannate.
Both polyamine and poly-DADMAC coagulants have been proven to be very effective at removing most suspended solids. Tannates are particularly good at oils and fats.
Inorganic coagulants include aluminium coagulants (e.g. aluminium sulphate, aluminium chloride and sodium aluminate) and iron coagulants (e.g. ferric sulphate, ferrous sulphate, ferric chloride and ferric chloride sulphate). Both have been proven to be very effective at removing most suspended solids.
FREE EBOOK: DISINFECTION SOLUTIONS FOR SAFE DRINKING WATER
Aluminium sulfate is the most commonly used chemical for coagulation in wastewater treatment. Additional commonly used coagulants include sodium aluminate, ferric sulfate, and ferric chloride.
Aluminium sulphate is the most widely used aluminium coagulant. It is available in a number of solid forms such as block, kibbled, or ground and is also available as a solution. When added to water, the acidic coagulant and the natural alkalinity of the water reacts to form an aluminium hydroxide floc, which usually consists of calcium bicarbonate. pH control is important in coagulation, for both the removal of turbidity and colour and also to maintain satisfactory minimum levels of dissolved residual aluminium in the clarified water.
Sodium aluminate is formed by combining sodium oxide and aluminium oxide. Solid forms of this chemical usually contain 70-80% sodium aluminate, while liquid forms contain around 30% sodium aluminate. Due to the low molecular weight of AI, sodium aluminate solutions reduce chemical sludge production compared to iron. Moreover, aluminates raise the alkalinity of the water, eliminating the need for lime or hydroxides.
Ferric sulfate is a type of iron coagulant that is often used in conjunction with chlorine and can provide a denser floc than aluminium sulfate. Compared to alum, ferric sulfate has some advantages; for example, the flock particles of ferric hydroxides have a higher density than alum flocks and are more easily removed by sedimentation. However, there are also disadvantages as it produces a significantly heavier hydroxide sludge and it is difficult to dissolve.
Ferric Chloride works as a flocculant and coagulant. It is versatile in the water treatment industry and is an alternative to ferric sulfate. It generally promotes faster sedimentation, especially in cold water. However, it is the less popular choice, as chloride can increase water’s corrosivity.
In water treatment, metal coagulants such as the ones listed above are commonly used. Availability and affordability are the key considerations that generally influence the coagulant used. Aluminium sulfate is commonly available and affordable as well as being very effective.
However, other types of coagulants are also available:
Following coagulation (“Charge Neutralisation”), a second process called flocculation must occur. This is the growth of small, neutral particles into larger particles. Flocculants are the agents which promote this clumping of fine particles into ‘floc’ that can then be readily separated from the water. They are invariably polymers.
The flocculation process is a gentle mixing stage that increases the size of the particles from micro-floc to large, visible suspended particles called pin-flocs. Additional collisions between pin-flocs cause them to produce even larger, ‘macro-flocs’. The flocculants aid in this by being long-chain polymers with low charge to involve entanglement, enhanced van der Waal’s forces, and hydrogen bonding between the particles. Once these flocs have reached an optimum size and strength, the water is ready for solids-liquid separation. This can be filtration, centrifugation, sedimentation, or flotation.
Polymers are a range of water-soluble macromolecular compounds that have the ability to stabilise or enhance flocculation of the constituents in a body of water. They are added as part of the flocculation process to help strengthen and increase the settling weight of the floc.
Polymers can be either natural or synthetic. Natural polymers also date back to ancient times, with Sanskrit literature from around 2000 BC referencing the use of crushed nuts to clarify water. Natural polymers are virtually free of toxins and are biodegradable. Synthetic polymers are more commonly used because they are more effective, reliable, reproducible, and cost-effective.
Coagulation and flocculation remove a large number of organic compounds as well as suspended particles, including inorganic precipitates. The process removes particles and dissolved matter; however, the water may still contain pathogens, including viruses and bacteria. Pathogens are generally only removed if they are attached to the dissolved substances that are removed by coagulation and flocculation.
This is the first step in wastewater treatment and turning it into potable water—coagulation and flocculation remove many of the particles that make it complicated to disinfect water. Thanks to coagulation and flocculation, a smaller amount of chlorine needs to be added to disinfect the water. And using less chlorine saves money and makes the water safer.
Coagulation and flocculation are two separate, crucial parts of water and wastewater treatment. Coagulation destabilises the minute suspended particles by static charge neutralisation, while flocculation helps them to bind together to form much bigger morphologies, so they can be more easily separated from the liquid phase.
At WCS Group, our range of coagulants and specially selected flocculants can significantly reduce sludge generation and create alternative disposable routes or new wastewater options for our customers. To find out more, get in touch.
Finally, there is increasing environmental scrutiny and major reputational risks if wastewater treatment environmental obligations are not fulfilled. Purchasing a wastewater treatment system may not be economically viable to begin with; however, hiring is an option before you build a case for capital funds.